Table 1 Task trainers reviewed

From: Development of a simulation technical competence curriculum for medical simulation fellows

Trainer

Setup

Teardown

Central line trainer

Inspection of insert and priming of fluids for insert

Inspection of insert and priming of fluids for insert. Clean and disinfect all surfaces per OEM manual. Placed in appropriate storage case and stowed in appropriate position (per OEM manual)

Arterial line trainer

Filling fluid reservoir, installing new artery tubing, inspecting, and installing arm tissue, priming fluid system

Draining of fluid reservoir, remove arm tissue, install new artery, add mixture of sterile water and 1–2cc isopropyl alcohol, prime system, repeat until system plumbing is clear, drain system. Clean and disinfect all surfaces per OEM manual. Place trainer in appropriate case for storage

Lumbar/epidural trainer

Inspection of tissue insert, priming, and or removal of air depending on LP or EP usage

Inspection of insert, prime fluid, or remove air. Place in appropriate storage case and stowed in appropriate position (per OEM manual)

Airway/intubation heads

Inspection of overall appearance, tears in tongue, broken teeth, holes/tears in lung bladders, lubricate airway with OEM-approved airway lubricant

Inspection of overall appearance, tears in tongue, broken teeth, holes/tears in lung bladders, wipe away excess airway lubricant, Clean and disinfect all surfaces per OEM manual. Place in appropriate storage case

Trauma man

Inspection of simulator skin, selection and installation of appropriate tissue insert

Inspection of simulator skin, removal of used tissue inserts. Clean and disinfect all surfaces per OEM manual. Place in appropriate storage case

  1. OEM original equipment manufacturer